BC9050

BC9000, BC9050 | Ethernet TCP/IP Bus Terminal Controllers

ساخت بکهوف

BECKHOFF

اریجینال - استفاده در اکثر صنایع

اطلاعات بیشتر:



BC9000, BC9050 | Ethernet TCP/IP Bus Terminal Controllers

The Bus Terminal Controller is programmed using the TwinCAT programming system according to IEC 61131-3. The configuration/programming interface of the BC9000 or BC9050 is used for loading the PLC program. If the software PLC TwinCAT is in use, the PLC program can also be loaded via Ethernet.

In the default setting the inputs and outputs of the connected Bus Terminals are assigned to the controller. Each Bus Terminal can be configured in such a way that it exchanges data directly through the fieldbus with the higher-level automation device.

Controller for distributed signal processing

The BC9000 and BC9050 Bus Terminal Controllers support the operation of all Bus Terminal types. As far as the user is concerned, the inputs and outputs are not handled any differently from the way they are by other coupler series. The information is made available for use as a byte array in the process image of the automation device.

The analog and multi-functional Bus Terminals can be adapted to each specific application using the KS2000 configuration set. Depending on the type, the analog Bus Terminals' registers contain temperature ranges, gain values and linearisation characteristics. With the KS2000, the required parameters can be set on a PC. The Bus Terminals store settings permanently and in a fail-safe manner.

Having the controller (PLC, IPC) carry out the configuration of the Bus Terminals is a further option. The PLC or IPC uses function blocks (FB) to take care of the configuration of all the peripherals during the start-up phase. The controller can, if required, upload the non-centrally generated configuration data in order to manage and store them centrally. This means that it is not necessary to carry out the setting procedure again if a Bus Terminal is exchanged. The controller carries out the desired setting automatically after switching on.

PLC dataEthernet TCP/IP | BC9000BC9050
Programmingvia TwinCAT and programming interface or Ethernet
Program memory64/96 kbytes48 kbytes
Data memory64/128 kbytes32 kbytes
Remanent data4,080 bytes2 kbytes
Runtime system1 PLC task
PLC cycle timeapprox. 1.5 ms for 1,000 instructions (without I/O cycle, K-bus)
Programming languagesIEC 61131-3 (IL, LD, FBD, SFC, ST)
Online change–yes
Technical dataBC9000BC9050
Number of Bus Terminals6464 (255 with K-bus extension)
Max. number of bytes fieldbus512 byte input and 512 byte output
Max. number of bytes process image512 byte input and 512 byte output2,048 byte input and 2,048 byte output
Digital peripheral signals512 inputs/outputs2,040 inputs/outputs
Analog peripheral signals128 inputs/outputs512 inputs/outputs
ProtocolTwinCAT ADS, Modbus TCP
Configuration possibilityvia KS2000 or Ethernet
Data transfer rates10/100 Mbaud, automatic recognition of the transmission rate
Bus interface1 x RJ 45
Power supply24 V DC (-15 %/+20 %)
Input current70 mA + (total K-bus current)/4, 500 mA max.320 mA max.
Starting current2.5 x continuous current
Recommended fuse≤ 10 A
Current supply K-bus1,750 mA1,000 mA
Power contacts24 V DC max./10 A max.
Electrical isolation500 V (power contact/supply voltage/fieldbus)
Weightapprox. 170 gapprox. 100 g
Operating/storage temperature-25…+60 °C/-40…+85 °C0…+55 °C/-25…+85 °C
Protect. class/installation pos.IP 20/variable
ApprovalsCE, UL, Ex, GLCE, UL, Ex
Accessories 
KS2000configuration software for extended parameterisation
TwinCAT PLCprogramming system conforms to IEC 61131-3
Cordsetscordsets and connectors
FC90xx-00xxPC Fieldbus Cards with PCI interface
Ordering informationDescription
BC9000Ethernet Bus Terminal Controller for up to 64 Bus Terminals
BC9050Ethernet “Compact“ Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension)
BC9020Ethernet TCP/IP “Economy plus” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension)
BC9100Ethernet TCP/IP Bus Terminal Controller for up to 64 Bus Terminals (with integrated 2-channel switch)
BC9120Ethernet TCP/IP “Economy plus” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension, with integrated 2-channel switch)
BX9000Ethernet Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension)
BK9xx0Ethernet Bus Coupler
CX8090Ethernet Embedded PC
System 
Ethernet TCP/IPFor further Ethernet TCP/IP products please see the system overview


خریدBC9050

فروشBC9050

قیمتBC9050

مشخصاتBC9050

خرید BC9050

فروش BC9050

قیمت BC9050

مشخصات BC9050



مشخصات محصول مشاوره قبل از خرید

جستجوی مرتبط
- - BC9000, BC9050 | Ethernet TCP/IP Bus Terminal Controllers - - ساخت بکهوف - - BECKHOFF - - اریجینال - استفاده در اکثر صنایع - - اطلاعات بیشتر: - - BC9000, BC9050 | Ethernet TCP/IP Bus Terminal Controllers - - The Bus Terminal Controllers BC90x0 are Bus Couplers with integrated PLC functionality and have a fieldbus interface for Ethernet. They are intelligent slaves that can be used as a non-central intelligence in the Ethernet system. One unit consists of the Bus Terminal Controller, any number of terminals between 1 and 64, and a bus end terminal. The “Compact” BK9050 Bus Terminal Controller is a cost-optimised version with compact housing. With the K-bus extension, up to 255 Bus Terminals can be connected. - - The Bus Terminal Controller is programmed using the TwinCAT programming system according to IEC 61131-3. The configuration/programming interface of the BC9000 or BC9050 is used for loading the PLC program. If the software PLC TwinCAT is in use, the PLC program can also be loaded via Ethernet. - - In the default setting the inputs and outputs of the connected Bus Terminals are assigned to the controller. Each Bus Terminal can be configured in such a way that it exchanges data directly through the fieldbus with the higher-level automation device. - Controller for distributed signal processing - - The BC9000 and BC9050 Bus Terminal Controllers support the operation of all Bus Terminal types. As far as the user is concerned, the inputs and outputs are not handled any differently from the way they are by other coupler series. The information is made available for use as a byte array in the process image of the automation device. - - The analog and multi-functional Bus Terminals can be adapted to each specific application using the KS2000 configuration set. Depending on the type, the analog Bus Terminals' registers contain temperature ranges, gain values and linearisation characteristics. With the KS2000, the required parameters can be set on a PC. The Bus Terminals store settings permanently and in a fail-safe manner. - - Having the controller (PLC, IPC) carry out the configuration of the Bus Terminals is a further option. The PLC or IPC uses function blocks (FB) to take care of the configuration of all the peripherals during the start-up phase. The controller can, if required, upload the non-centrally generated configuration data in order to manage and store them centrally. This means that it is not necessary to carry out the setting procedure again if a Bus Terminal is exchanged. The controller carries out the desired setting automatically after switching on. - PLC data Ethernet TCP/IP | BC9000 BC9050 - Programming via TwinCAT and programming interface or Ethernet - Program memory 64/96 kbytes 48 kbytes - Data memory 64/128 kbytes 32 kbytes - Remanent data 4,080 bytes 2 kbytes - Runtime system 1 PLC task - PLC cycle time approx. 1.5 ms for 1,000 instructions (without I/O cycle, K-bus) - Programming languages IEC 61131-3 (IL, LD, FBD, SFC, ST) - Online change – yes - Technical data BC9000 BC9050 - Number of Bus Terminals 64 64 (255 with K-bus extension) - Max. number of bytes fieldbus 512 byte input and 512 byte output - Max. number of bytes process image 512 byte input and 512 byte output 2,048 byte input and 2,048 byte output - Digital peripheral signals 512 inputs/outputs 2,040 inputs/outputs - Analog peripheral signals 128 inputs/outputs 512 inputs/outputs - Protocol TwinCAT ADS, Modbus TCP - Configuration possibility via KS2000 or Ethernet - Data transfer rates 10/100 Mbaud, automatic recognition of the transmission rate - Bus interface 1 x RJ 45 - Power supply 24 V DC (-15 %/+20 %) - Input current 70 mA + (total K-bus current)/4, 500 mA max. 320 mA max. - Starting current 2.5 x continuous current - Recommended fuse ≤ 10 A - Current supply K-bus 1,750 mA 1,000 mA - Power contacts 24 V DC max./10 A max. - Electrical isolation 500 V (power contact/supply voltage/fieldbus) - Weight approx. 170 g approx. 100 g - Operating/storage temperature -25…+60 °C/-40…+85 °C 0…+55 °C/-25…+85 °C - Protect. class/installation pos. IP 20/variable - Approvals CE, UL, Ex, GL CE, UL, Ex - Accessories - KS2000 configuration software for extended parameterisation - TwinCAT PLC programming system conforms to IEC 61131-3 - Cordsets cordsets and connectors - FC90xx-00xx PC Fieldbus Cards with PCI interface - Ordering information Description - BC9000 Ethernet Bus Terminal Controller for up to 64 Bus Terminals - BC9050 Ethernet “Compact“ Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) - BC9020 Ethernet TCP/IP “Economy plus” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) - BC9100 Ethernet TCP/IP Bus Terminal Controller for up to 64 Bus Terminals (with integrated 2-channel switch) - BC9120 Ethernet TCP/IP “Economy plus” Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension, with integrated 2-channel switch) - BX9000 Ethernet Bus Terminal Controller for up to 64 Bus Terminals (255 with K-bus extension) - BK9xx0 Ethernet Bus Coupler - CX8090 Ethernet Embedded PC - System - Ethernet TCP/IP For further Ethernet TCP/IP products please see the system overview - - خریدBC9050 - - فروشBC9050 - - قیمتBC9050 - - مشخصاتBC9050 - - خرید BC9050 - - فروش BC9050 - - قیمت BC9050 - - مشخصات BC9050 - - -
تازه های این گروه
KL2809 - 1393/4/23

KL2809 | HD Bus Terminal, 16-channel digital output 24 V DC ترمینال باس ساخت بکهوف اریجینال BECKHOFF...

BC9050 - 1393/4/23

BC9000, BC9050 | Ethernet TCP/IP Bus Terminal Controllers ساخت بکهوف BECKHOFF اریجینال...

KL1809 - 1393/4/23

KL1809, KL1819 | HD Bus Terminals, 16-channel digital input 24 V D ساخت بکهوف اریجینال...

KL9010 - 1393/4/23

KL9010 | End terminal ساخت بکهوف اریجینال BECHKOFF ...

صفحات :1 2 
محصولات مرتبط
6ES7407-0RA02-0AA0/6ES7 407-0RA02-0AA0 - 1394/9/2

SIMATIC S7-400, POWER SUPPLY PS407, 20A, WIDERANGE, 120/230V UC, 5V DC/20A منبع تغذیه 5 ولت 20 آمپر اریجینال المان - واردات از انگلیس...

EER42X15/EER4215 - 1394/8/2

ترانس خروجی(جریان) دستگاه جوش در برد وسط دستگاه های ماسفتی 22:4 نمایندگی انحصاری HS در ایران...

HG-DTYR2UD-D-34/DTYR2UD-D-34 - 1394/8/19

ال ای دی اوال اچ جی اصلی (100% اریجینال - با بارکد اصلی ATRIN Ùˆ کنترل کیفیت Ùˆ نشانگذاری شده توسط کمپانی HG) شدت روشنایی 1200-1400 MCD IF:15-20mA VF:2-2.2V -620-625nm /طریقه آشنایی با hg اریجینØ...

FMH23N50E/23N50E/23N50 - 1391/7/4

N-CHANNEL SILICON POWER MOSFET,500V,23A,FUJI JAPAN,23N50 IRFP23N50 ماسفت قدرت فوجی ژاپن...

صفحات :1 2 3 4 5 6 7 8 9 10 11 12 13 14  » »
جستجوی قطعه
عنوان:
گروه:
جستجو در: عنوان محصول    
شرح مختصر    
شرح کامل    
دیگر موارد    
 
نماد اعتماد الکترونیکی
برندهای موجود
رهگیری سفارش
قطعات پرفروش
› IRFP4227
› FMH23N50E/23N50E/23N50
› ATMEGA8A-PU
› 47D15/47D-15
نظرسنجی سایت

نقطه ضعف این فروشگاه چیست ؟

کیفیت قطعات
خدمات پس از فروش
پاسخگویی و اطلاعات کم فروشنده
قیمت قطعات



خبرنامه
نام:
ایمیل:
تلفن: